Description
Gas detector for Alcohol and Solvents.
Explosion proof Ex-d execution.
ATEX certified.
Microprocessor control.
Automatic zero compensation.
Analog output 0-5V.
Two relay output (prealarm – alarm) with threshold level regulation.
Rivelatore di Alcool e Solventi. Esecuzione antideflagrante Ex-d. Certificazione ATEX.
Gas detector for Alcohol and Solvents.
Explosion proof Ex-d execution.
ATEX certified.
Microprocessor control.
Automatic zero compensation.
Analog output 0-5V.
Two relay output (prealarm – alarm) with threshold level regulation.
Power supply | 12 – 24 Vcc (+/-15%) |
---|---|
Operating current | 2W |
Operating temperature | -10 +40 |
Umidità | 0-95% |
Measuring range. | 0 – 4.000 ppm di alcool isopropilico in aria |
Outputs | 0 – 5V e uscita con 2 relè associati a 2 soglie di intervento impostate al 2.000 e 4.000 ppm di alcool |
GAS type | Acool e Solventi |
Case | Antideflagrante |
Index of protection | IP65 |
Dimensions | 150x100x70 mm |
Weight | 600gr |
Certifications | CESI EX – 96.108 X/N – ATEX TUV 05 ATEX 2907 X |